CHAPTER68 Configuration Parameters Reference
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
'Play Ringback Tone to IP'
configure voip > sip-
definition settings >
play-rbt-2ip
[PlayRBTone2IP]
Global parameter that enables the device to play a
ringback tone to the IP side for IP-to-Tel calls. You can
also configure this feature per specific calls, using IP
Profiles (IpProfile_PlayRBTone2IP). For a detailed
description of the parameter and for configuring this
feature in the IP Profiles table, see Configuring IP
Profiles.
Note: If this feature is configured for a specific IP
Profile, the settings of this global parameter is ignored
for calls associated with the IP Profile.
'Play Local RBT on ISDN Transfer'
play-l-rbt-isdn-trsfr
[PlayRBTOnISDNTransfer]
Determines whether the device plays a local ringback
tone for ISDN's Two B Channel Transfer (TBCT),
Release Line Trunk (RLT), or Explicit Call Transfer
(ECT) call transfers to the originator when the second
leg receives an ISDN Alerting or Progress message.
â–  [0] Don't Play (default)
â–  [1] Play
Note:
â–  For Blind transfer, the local ringback tone is played
to first call PSTN party when the second leg
receives the ISDN Alerting or Progress message.
â–  For Consulted transfer, the local ringback tone is
played when the second leg receives ISDN Alerting
or Progress message if the Progress message is
received after a SIP REFER.
â–  The parameter is applicable only if the parameter
SendISDNTransferOnConnect is set to 1.
â–  The parameter is applicable only to digital
interfaces.
'MFC R2 Category'
mfcr2-category
[R2Category]
Defines the tone for MFC R2 calling party category
(CPC). The parameter provides information on the
calling party such as National or International call,
Operator or Subscriber and Subscriber priority.
The value range is 1 to 15 (defining one of the MFC R2
tones). The default is 1.
Note: The parameter is applicable only to digital
interfaces.
Tone Detection Parameters
The signal tone detection parameters are described in the table below.
Table 68-56:Tone Detection Parameters
Parameter Description
DTMF-detector-enable
[DTMFDetectorEnable]
Enables the detection of DTMF signaling.
â–  [0] = Disable