CHAPTER68 Configuration Parameters Reference
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
configure voip > gateway dtmf-
supp-service supp-service-
settings > nrt-subscription
[EnableNRTSubscription]
â–  [0] Disable (default)
â–  [1] Enable
'AS Subscribe IP Group ID'
configure voip > gateway dtmf-
supp-service supp-service-
settings > as-subs-ipgroupid
[ASSubscribeIPGroupID]
Defines the IP Group ID that contains the
Application server for Subscription.
The valid value range is 1 to 8. The default is
-1 (i.e., not configured).
'NRT Subscribe Retry Time'
configure voip > gateway dtmf-
supp-service supp-service-
settings > nrt-sub-retry-time
[NRTSubscribeRetryTime]
Defines the Retry period (in seconds) for
Dialog subscription if a previous request
failed.
The valid value range is 10 to 7200. The
default is 120.
'Call Forward Ring Tone ID'
configure voip > gateway dtmf-
supp-service supp-service-
settings > cfe-ring-tone-id
[CallForwardRingToneID]
Defines the ringing tone type played when
call forward notification is accepted.
The valid value range is 1 to 5. The default is
1.
Message Waiting Indication Parameters
The message waiting indication (MWI) parameters are described in the table below.
Table 68-42:MWI Parameters
Parameter Description
'Enable MWI'
configure voip > gateway
dtmf-supp-service supp-
service-settings >
enable-mwi
[EnableMWI]
Enables Message Waiting Indication (MWI).
â–  [0] Disable (default)
â–  [1] Enable
Note:
â–  The parameter is applicable only to FXS interfaces.
â–  The device supports only the receipt of SIP MWI
NOTIFY messages (the device doesn't generate
these messages).
â–  For more information on MWI, see Message
Waiting Indication.
'MWI Analog Lamp'
configure voip > gateway
dtmf-supp-service supp-
service-settings > mwi-
analog-lamp
[MWIAnalogLamp]
Global parameter enabling the visual display of MWI.
You can also configure the feature per specific calls,
using Tel Profiles (TelProfile_MWIAnalog). For a
detailed description of the parameter and for configuring
the feature in the Tel Profiles table, see Configuring Tel
Profiles.
Note: