CHAPTER58 Syslog and Debug Recording
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
To capture traffic of all trunks, configure the 'Value'
parameter (above) to "-1".
You must configure the trace level for the trunks that you
want to trace. This is done using the 'Trace Level'
parameter on the Trunk Settings page (see Configuring
Trunk Settings on page527).
[5] CDR Only = Only CDRs are generated. The option is
applicable only if the 'Log Destination' parameter is configured
to Syslog Server or Local Storage. When configured to
Syslog Server, only CDRs are included in the Syslog
messages (excluding all system logs and alerts) sent to the
Syslog server.
[6] Call Flow = The device sends SIP messages (in XML
format), as they occur in real-time, to OVOC for displaying SIP
call dialog sessions as call flow diagrams. For this functionality,
you also need to configure the 'Log Destination' parameter to
Call Flow Server. For enabling this functionality, see Enabling
SIP Call Flow Diagrams in OVOC on page1061.
[7] SIP Only = The option is applicable only to debug recording
(i.e. the 'Log Destination' parameter is configured to Debug
Recording Server or Syslog Server). The debug recording
includes only SIP messages.
Note:
If you configure the 'Log Destination' parameter to Local
Storage, you must configure the 'Log Type' parameter to CDR
Only.
PSTN debug traces may affect performance.
The parameter is not applicable when the 'Filter Type' parameter
is configured to IP Trace.
To include Syslog messages in debug recording, it is
unnecessary to enable Syslog functionality.
'Mode'
mode
[LoggingFilters_Mode]
Enables and disables the rule.
[0] Disable
[1] Enable (default)
Filtering IP Network Traces
You can filter Syslog and debug recording messages for IP network traces, by configuring the 'Filter
Type' parameter to IP Trace in the Logging Filters table. IP traces are used to record any IP stream
, according to destination and/or source IP address, or port and Layer-4 protocol (UDP, TCP or any
other IP type as defined by http://www.iana.com). Network traces are typically used to record
HTTP.
When the IP Trace option is selected, only the ‘Value parameter is applicable; the 'Syslog' and
'Capture Type' parameters are not relevant. The 'Value' parameter configures the Wireshark-like
filtering expressions for your IP trace. The following Wireshark-like expressions are supported: