CHAPTER68 Configuration Parameters Reference
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
[CurrentDisconnectDefaultThreshold] Defines the line voltage threshold at which a current
disconnect detection is considered.
The valid range is 0 to 20 Volts. The default is 4 Volts.
Note:
â– The parameter is applicable only to FXO
interfaces.
â– For the parameter to take effect, a device reset is
required.
configure voip > interface
fxs-fxo > time-to-sample-
analog-line-voltage
[TimeToSampleAnalogLineVoltage]
Defines the frequency at which the analog line
voltage is sampled (after offhook), for detection of the
current disconnect threshold.
The valid range is 100 to 2500 msec. The default is
1000 msec.
Note:
â– The parameter is applicable only to FXO
interfaces.
â– For the parameter to take effect, a device reset is
required.
SBC Parameters
The SBC and CRP parameters are described in the table below.
Table 68-64:SBC and CRP Parameters
Parameter Description
CRP-specific Parameters
configure voip > application >
enable-crp
[EnableCRPApplication]
Enables the CRP application.
â– [0] = Disable (default)
â– [1] = Enable
Note: For the parameter to take effect, a
device reset is required.
'CRP Survivability Mode'
configure voip > sbc settings >
crp-survivability-mode
[CRPSurvivabilityMode]
Defines the CRP mode.
â– [0] Standard Mode (default)
â– [1] Always Emergency Mode
â– [2] Auto-answer REGISTER
'CRP Gateway Fallback'
configure voip > sbc settings >
crp-gw-fallback
[CRPGatewayFallback]
Enables fallback routing from the proxy
server to the Gateway (PSTN).
â– [0] Disable (default)
â– [1] Enable
SBC-specific Parameters
- 1335 -