Parameter Description
'Generated Register Interval'
configure voip > sip-
definition proxy-and-
registrationsip-
definition settings >
gen-reg-int
[GeneratedRegistersInterval]
Defines the rate (in seconds) at which the device sends
user register requests (REGISTER messages). The
parameter is based on the maximum number of
REGISTER messages that can be sent at this rate,
configured by the MaxGeneratedRegistersRate
parameter.
The valid value is 1 to 5. The default is 1.
Configuration examples:
â–  If you configure the MaxGeneratedRegistersRate
parameter to 100 and the
GeneratedRegistersInterval to 5, the device sends a
maximum of 20 REGISTER messages per second
(i.e., 100 messages divided by 5 sec; 100 per 5
seconds).
â–  If you configure the MaxGeneratedRegistersRate
parameter to 100 and the
GeneratedRegistersInterval to 1, the device sends a
maximum of a 100 REGISTER messages per
second.
configure voip > sip-
definition settings >
account-invite-failure-
trigger-codes
[AccountInviteFailureTriggerCodes]
Defines SIP response codes that if received for a failed
INVITE message sent for an Account, triggers the
device to re-register the Account. The parameter is
applicable only if the Account's 'Re-Register on Invite
Failure' parameter in the Accounts table is configured to
Enable (see Configuring Registration Accounts on
page459).
The valid value is a SIP response code. Multiple
response codes can be configured, where each value is
separated by a comma. The default is "403,408,480"
(without quotation marks).
Note: SIP response code 408 also refers to an INVITE
timeout (i.e., no reply from server). Therefore, if re-
registration is needed for such a scenario, make sure
that you configure the parameter with "408" as well.
Network Application Parameters
The SIP network application parameters are described in the table below.
Table 68-29:SIP Network Application Parameters
Parameter Description
configure voip > sip-
definition settings > tcp-
keepalive-time
[TCPKeepAliveTime]
Defines the interval (in sec) between the last data
packet sent and the first keep-alive probe to send.
The valid value is 10 to 65,000. The default is 60.
Note:
â–  Simple ACKs such as keepalives are not
considered data packets.