Mediant 1000 Gateway & E-SBC | User's Manual
Table 15-4: Approximate AMD High Detection Sensitivity - Parameter Suite 1 (Based on North Amer-
ican English)
AMD Detection Sensitivity
Level
Performance
Success Rate for Live
Calls
Success Rate for Answering
Machine
0
(Best for Answering Machine)
72% 97%
1 77% 96%
2 79% 95%
3 80% 95%
4 84% 94%
5 86% 93%
6 87% 92%
7 88% 91%
8 90% 89%
9 90% 88%
10 91% 87%
11 94% 78%
12 94% 73%
13 95% 65%
14 96% 62%
15
(Best for Live Calls)
97% 46%
Configuring AMD
You can configure AMD for all calls using global AMD parameters or for specific calls using IP
Profiles. The procedure below describes how to configure AMD for all calls. To configure AMD for
specific calls, use the AMD parameters in the IP Profiles table (see Configuring IP Profiles)
For the Gateway appplication, you can configure AMD per call based on the called number or Trunk
Group. This is done by configuring AMD for a specific IP Profile and then assigning the IP Profile to
a Trunk Group in the IP-to-Tel Routing table (see Configuring IP-to-Tel Routing Rules).
➢ To configure AMD for all calls:
1. Open the DSP Settings page (Setup menu > Signaling & Media tab > Media folder > DSP
Settings):
2. From the 'IPMedia Detectors' drop-down list (EnableDSPIPMDetectors), select Enable .