CHAPTER45 License Key
Mediant 1000 Gateway & E-SBC | User's Manual
Figure 45-4: Customizing Allocation Profile
When configuring your own customized profile (i.e., using the Custom option), the
Transcoding Session capacity license cannot be changed in the 'Allocation' field.
However, you can reduce the license using its corresponding 'Limit' field, as described
below.
6. Reset the device with a burn-to-flash for your settings to take effect.
7. Once you have configured the Allocation Profile, you can modify each SBC license capacity
without resetting the device. To do this, select the check box corresponding to the license type
you want to modify, and then in the corresponding 'Limit' field, enter a new value, and then click
Apply. The figure below shows an example of changing the Far End User license capacity to
10:
Figure 45-5: Configuring Limits for Allocation Profile
Viewing Floating License Reports
You can view the SBC resource consumption (signaling sessions, media sessions, transcoding
sessions, and far-end user registrations) reports of the Floating License that the device periodically
sends to OVOC.
The Floating License Reports page is available only if you have enabled the Floating
License feature (see SBC Capacity Licenses from Floating License on page878).
- 881 -