CHAPTER68 Configuration Parameters Reference
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
Answer Detector (AD) Parameters
'Enable Answer Detector'
[EnableAnswerDetector]
Currently, not supported.
'Answer Detector Activity Delay'
configure voip > media
ipmedia > answer-
detector-activativity-
delay
[AnswerDetectorActivityDelay]
Defines the time (in 100-msec resolution) between
activating the Answer Detector and the time that the
detector actually starts to operate.
The valid range is 0 to 1023. The default is 0.
'Answer Detector Silence Time'
[AnswerDetectorSilenceTime]
Currently, not supported.
'Answer Detector Redirection'
[AnswerDetectorRedirection]
Currently, not supported.
'Answer Detector Sensitivity'
configure voip > media
ipmedia > answer-
detector-sensitivity
[AnswerDetectorSensitivity]
Defines the Answer Detector sensitivity.
The range is 0 (most sensitive) to 2 (least sensitive). The
default is 0.
Coder Parameters
The coder parameters are described in the table below.
Table 68-32:Coder Parameters
Parameter Description
configure voip > media
settings > EVRC-VAD-
enable
[EnableEVRCVAD]
Enables the EVRC voice activity detector.
[0] = Disable (default)
[1] = Enable
Note: The parameter is applicable only to the EVRC and
EVRC-B coders.
configure voip > media
settings > EVRC-dtx-min
[EVRCDTXMin]
Defines the minimum gap between two SID frames when
using the EVRC voice activity detector. Units are in
EVRC frame size (20 msec).
The range is 0 to 20000. The default is 12.
Note: The parameter is applicable only to the EVRC and
EVRC-B coders.
configure voip > media
settings > EVRC-dtx-max
[EVRCDTXMax]
Defines the maximum gap between two SID frames when
using the EVRC voice activity detector. Units are in
EVRC frame size (20 msec).
The range is 0 to 20000. The default is 32.
Note: The parameter is applicable only to the EVRC and
EVRC-B coders.