CHAPTER58 Syslog and Debug Recording
Mediant 1000 Gateway & E-SBC | User's Manual
3. Define a source and/or destination IP address to be captured (any|ipv4_address|ipv6_
address):
# debug capture voip interface vlan <VLAN ID> proto <Protocol> host <IP Address>
At this stage, you can press Enter to output the capture to the CLI terminal window, or you can
continue with the next step to configure additional commands.
4. Define a source and/or destination port number to be captured (any|[1-65535]):
# debug capture voip interface vlan <VLAN ID> proto <Protocol> host <IP Address>
port <Port>
At this stage, you can press Enter to output the capture to the CLI terminal window, or you can
continue with the next step to configure additional commands.
5. Define the IP address (IPv4) of the server (TFTP or FTP) to where you want the device to send
the captured file:
# debug capture voip interface vlan <VLAN ID> proto <Protocol> host <IP Address>
ftp-server|tftp-server <IP Address>
6. Press Enter to save the capture to a file on the device.
7. Press the CTRL + C key-combination to stop the capture and to send the file to the defined
server.