CHAPTER8 SNMP-Based Management
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
✔ If configured to any value
other than Suppressed, the
device always sends the
alarm with the configured
severity (regardless of
condition).
â–  [1] Indeterminate
â–  [2] Warning
â–  [3] Minor
â–  [4] Major
â–  [5] Critical
Customized Severity
alarm-customized-severity
[AlarmSeverity_CustomizedSeverity]
Defines the new (customized)
severity of the alarm. This severity
replaces the alarm's original severity
that you specified in the 'Original
Severity' parameter. For example, if
you want to change the severity of the
acCertificateExpiryAlarm alarm from
Minor to Major, then configure the
'Original Severity' parameter to Minor
and the 'Customized Severity'
parameter to Major.
â–  [0] Suppressed = Disables
(suppresses) the alarm or a
specified severity, depending on
the 'Original Severity' parameter:
✔ To suppress an alarm:
Configure the 'Original
Severity' parameter to
Default, or if the alarm has
only one severity level,
configure the 'Original
Severity' parameter to this
severity. For example, as the
acBoardConfigurationError
alarm is only sent with Critical
severity, configure the
'Original Severity' parameter
to Critical.