CHAPTER65 Testing SIP Signaling Calls
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
'Call Party'
call-party
[Test_Call_CallParty]
Defines whether the test endpoint is the initiator (caller) or
receiving side (called) of the test call.
â–  [0] Caller (default)
â–  [1] Called
'Maximum Channels for Session'
max-channels
[Test_Call_MaxChannels]
Defines the maximum number of concurrent channels for
the test session. For example, if you have configured an
endpoint "101" and you configure the parameter to "3", the
device automatically creates three simulated endpoints -
"101", "102" and "103" (i.e., consecutive endpoint URIs
are assigned).
The default is 1.
'Call Duration'
call-duration
[Test_Call_CallDuration]
Defines the call duration (in seconds).
The valid value is -1 to 100000. The default is 20. A value
of 0 means infinite. A value of -1 means that the
parameter value is automatically calculated according to
the values of the 'Calls per Second' and 'Maximum
Channels for Session' parameters.
Note: The parameter is applicable only if you configure
'Call Party' to Caller.
'Calls per Second'
calls-per-second
[Test_Call_CallsPerSecond]
Defines the number of calls per second.
Note: The parameter is applicable only if you configure
'Call Party' to Caller.
'Test Mode'
test-mode
[Test_Call_TestMode]
Defines the test session mode.
â–  [0] Once = (Default) The test runs until the lowest
value between the following is reached:
✔ Maximum channels is reached for the test
session, configured by 'Maximum Channels for
Session'.
✔ Call duration ('Call Duration') multiplied by calls
per second ('Calls per Second').
✔ Test duration expires, configured by 'Test
Duration'.
â–  [1] Continuous = The test runs until the configured
test duration is reached. If it reaches the maximum
channels configured for the test session (in the
'Maximum Channels for Session'), it waits until the
configured call duration of a currently established
tested call expires before making the next test call. In
this way, the test session stays within the configured
maximum channels.
Note: The parameter is applicable only if you configure
'Call Party' to Caller.
'Test Duration'
test-duration
[Test_Call_TestDuration]
Defines the test duration (in minutes).
The valid value is 0 to 100000. The default is 0 (i.e.,
unlimited).
- 1074 -