CHAPTER68 Configuration Parameters Reference
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
✔ The device terminates a call due to the receipt
of a 408 (Request Timeout) response and the
only provisional response the device has
received for the call is the 100 Trying
provisional response (indicative of a home
proxy server failure).
Note: The parameter is applicable only to the Gateway
application.
'ReRegister On Connection Failure'
configure voip > sip-
definition proxy-and-
registration > reg-on-
conn-failure
[ReRegisterOnConnectionFailure]
Enables the device to perform SIP re-registration upon
TCP/TLS connection failure.
â–  [0] Disable (default)
â–  [1] Enable
'Gateway Registration Name'
configure voip > sip-
definition proxy-and-
registration > gw-
registration-name
[GWRegistrationName]
Defines the user name that is used in the From and To
headers in SIP REGISTER messages. If no value is
specified (default) for the parameter, the UserName
parameter is used instead.
Note:
â–  The parameter is applicable only to the Gateway
application.
â–  The parameter is applicable only for single
registration per device (i.e., AuthenticationMode is
set to 1). When the device registers each channel
separately (i.e., AuthenticationMode is set to 0), the
user name is set to the channel's phone number.
'Registration Mode'
configure voip > sip-
definition proxy-and-
registration >
authentication-mode
[AuthenticationMode]
Determines the device's registration and authentication
method.
â–  [0] Per Endpoint = Registration and authentication
is performed separately for each endpoint or B-
channel. This is typically used for FXS interfaces,
where each endpoint registers (and authenticates)
separately with its user name and password.
â–  [1] Per Gateway = (Default) Single registration and
authentication for the entire device. This is typically
used for FXO interfaces and digital interfaces.
â–  [3] Per FXS = Registration and authentication for
FXS endpoints.
Note: The parameter is applicable only to the Gateway
application.
'Set Out-Of-Service On
Registration Failure'
configure voip > sip-
definition proxy-and-
registration > set-oos-
on-reg-failure
[OOSOnRegistrationFail]
Enables setting the endpoint, trunk, or entire device
(i.e., all endpoints) to out-of-service if registration fails.
â–  [0] Disable (default)
â–  [1] Enable
- 1156 -