EasyManuals Logo

AudioCodes E-SBC User Manual

AudioCodes E-SBC
1414 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1368 background imageLoading...
Page #1368 background image
CHAPTER68 Configuration Parameters Reference
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
'Send Digit Pattern on Connect'
configure voip > sip-
definition settings >
digit-pttrn-on-conn
[TelConnectCode]
Defines a digit pattern to send to the Tel side after a
SIP 200 OK is received from the IP side. The digit
pattern is a user-defined DTMF sequence that is used
to indicate an answer signal (e.g., for billing).
The valid value is up to 8 characters.
Note: The parameter is applicable only to FXO and
CAS.
'Broken Connection Mode'
configure voip > sip-
definition settings > disc-
broken-conn
[DisconnectOnBrokenConnection]
Global parameter that defines the device's handling of
calls if RTP packets are not received within a user-
defined timeout, configured by the
[BrokenConnectionEventTimeout] parameter. You
can also configure this feature per specific calls,
using IP Profiles (IpProfile_
DisconnectOnBrokenConnection). For a detailed
description of the parameter and for configuring this
feature in the IP Profiles table, see Configuring IP
Profiles.
Note: If this feature is configured for a specific IP
Profile, the settings of this global parameter is ignored
for calls associated with the IP Profile.
'Broken Connection Timeout'
configure voip > sip-
definition settings >
broken-connection-event-
timeout
[BrokenConnectionEventTimeout]
Defines the timeout interval (in 100-msec units) after
which a call is disconnected if RTP packets are not
received during an established call (i.e., RTP flow
suddenly stops during the call).
The valid range is from 3 (i.e., 300 msec) to approx.
2684354 (i.e., 74.5 hours). The default is 100 (i.e.,
10,000 msec or 10 seconds).
Note:
â–  The parameter is applicable only if the
[DisconnectOnBrokenConnection] parameter is
configured to [1].
â–  Currently, the feature functions only if Silence
Suppression is disabled.
configure voip > sbc
settings > no-rtp-
detection-timeout
[NoRTPDetectionTimeout]
Defines the timeout interval (in msec) after which a
call is disconnected if RTP packets are not received
within the interval. The timer begins from call setup
and if no packets are received when the timer expires,
the device disconnects the call.
The valid range is 0 to 50000. The default is 0, which
means that this timeout feature is disabled and that
the device does not disconnect the call due to RTP
packets not being received.
Note:
- 1330 -

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes E-SBC and is the answer not in the manual?

AudioCodes E-SBC Specifications

General IconGeneral
BrandAudioCodes
ModelE-SBC
CategoryGateway
LanguageEnglish

Related product manuals