CHAPTER15 Media
Mediant 1000 Gateway & E-SBC | User's Manual
Each time the device detects the supported event, it sends an INFO message to the remote
party with the following message body:
Content-Type: Application/X-Detect
Type = [event type]
Subtype = [subtype of each event type]
The table below lists the event types and subtypes that can be detected by the device. The text
shown in the table are the strings used in the X-Detect header. The table also provides a summary
of the required configuration.
For SBC calls, event detection is enabled using the IPProfile_SBCHandleXDetect parameter in the
IP Profiles table (see Configuring IP Profiles).
Table 15-1: Supported X-Detect Event Types
Event
Type
Subtype Description and Required Configuration
AMD Voice (live voice)
Automata (answering
machine)
Silence (no voice)
Unknown
Beep (greeting
message of
answering machine)
Event detection using the AMD feature. For more
information, see Answering Machine Detection (AMD).
CPT SIT-NC
SIT-IC
SIT-VC
SIT-RO
Busy
Reorder
Ringtone
Beep (greeting
message of
answering message)
Event detection of tones using the CPT file.
1. Create a CPT file with the required tone types of the
events that you want to detect.
2. Install the CPT file on the device.
3. For SIT detection:
Set the SITDetectorEnable parameter to 1.
Set the UserDefinedToneDetectorEnable
parameter to 1.
Note:
For more information on SIT detection, see SIT Event
Detection.
To configure beep detection, see Detecting
Answering Machine Beep.
FAX CED Set the IsFaxUsed parameter to any value other than
0.
- or -
Set the IsFaxUsed parameter to 0 and the
FaxTransportMode parameter to any value other than
0.
Note: Applicable only to the Gateway application.
modem Set the VxxModemTransportType parameter to 3.
Note: Applicable only to the Gateway application.
PTT voice-start Set the EnableDSPIPMDetectors parameter to 1.