CHAPTER17 Quality of Experience
Mediant 1000 Gateway & E-SBC | User's Manual
3. Configure a QoE Profile according to the parameters described in the table below.
4. Click Apply.
Table 17-3: Quality of Experience Profile Table Parameter Descriptions
Parameter Description
'Index'
[QOEProfile_
Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
'Profile Name'
name
[QOEProfile_
Name]
Defines a descriptive name, which is used when associating the row in
other tables.
The valid value is a string of up to 20 characters.
Note: The parameter value cannot contain a forward slash (/).
'Sensitivity Level'
sensitivity-
level
[QOEProfile_
SensitivityLevel]
Defines the pre-configured threshold profile to use.
â– [0] User Defined = Need to define thresholds per monitored
parameter in the Quality of Experience Color Rules table.
â– [1] Low = Pre-configured low sensitivity thresholds.
â– [2] Medium = (Default) Pre-configured medium sensitivity
thresholds.
â– [3] High = Pre-configured high sensitivity thresholds. Reporting is
done for small fluctuations in parameter values.
5. In the Quality of Experience Profile table, select the row for which you want to configure QoE
thresholds, and then click the Quality of Experience Color Rules link located below the
table; the Quality of Experience Color Rules table appears.
6. Click New; the following dialog box appears:
7. Configure a rule according to the parameters described in the table below.
- 305 -