CHAPTER18 Core Entities
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
'Enable TCP Keepalive'
tcp-keepalive-enable
[SIPInterface_TCPKeepaliveEnable]
Enables the TCP Keep-Alive mechanism with the IP
entity on this SIP Interface. TCP keep-alive can be
used, for example, to keep a NAT entry open for
clients located behind a NAT server, or simply to
check that the connection to the IP entity is available.
■ [0] Disable (default)
■ [1] Enable
Note: To configure TCP keepalive, use the following
ini file parameters: TCPKeepAliveTime,
TCPKeepAliveInterval, and TCPKeepAliveRetry.
'Used By Routing Server'
used-by-routing-server
[SIPInterface_UsedByRoutingServer]
Enables the SIP Interface to be used by a third-party
routing server for call routing decisions.
■ [0] Not Used (default)
■ [1] Used
For more information on the third-party routing server
feature, see Centralized Third-Party Routing Server.
'Pre-Parsing Manipulation Set'
pre-parsing-man-set
[SIPInterface_
PreParsingManSetName]
Assigns a Pre-Parsing Manipulation Set to the SIP
Interface. This lets you apply pre-parsing SIP
message manipulation rules on any incoming SIP
message received on this SIP Interface.
By default, no Pre-Parsing Manipulation Set is
assigned.
To configure Pre-Parsing Manipulation Sets, see
Configuring Pre-parsing Manipulation Rules.
Note:
■ Pre-Parsing Manipulation is done only on
incoming calls.
■ The device performs Pre-Parsing Manipulation
before Pre-Classification Manipulation and
Classification.
'CAC Profile'
cac-profile
[SIPInterface_AdmissionProfile]
Assigns a Call Admission Control Profile (CAC rules)
to the SIP Interface.
By default, no value is defined.
To configure CAC Profiles, see Configuring Call
Admission Control on page756.
Classification
'Classification Failure Response
Type'
classification_fail_
response_type
[SIPInterface_
ClassificationFailureResponseType]
Defines the SIP response code that the device sends
if a received SIP request (OPTIONS, REGISTER, or
INVITE) fails the SBC Classification process.
The valid value can be a SIP response code from 400
through 699, or it can be set to 0 to not send any
response at all. The default response code is 500
(Server Internal Error).
- 337 -