CHAPTER19 Coders and Profiles
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
Note:
■ For more information on AGC, see Automatic Gain
Control (AGC).
■ The corresponding global parameter is EnableAGC.
Analog
'Enable Polarity Reversal'
polarity-rvrsl
[TelProfile_
EnableReversePolarity]
Enables the Polarity Reversal feature for call release.
■ [0] Disable (default)
■ [1] Enable = Enables polarity reversal:
✔ FXS Interfaces: The device changes the line
polarity on call answer and then changes it back on
call release.
✔ FXO Interfaces: The device sends a SIP 200 OK
response when polarity reversal signal is detected
(applicable only to one-stage dialing) and releases
a call when a second polarity reversal signal is
detected.
Note:
■ The parameter is applicable to FXS and FXO
interfaces.
■ The corresponding global parameter is
EnableReversalPolarity.
'Enable Current Disconnect'
current-disconnect
[TelProfile_
EnableCurrentDisconnect]
Enables call release upon detection of a Current
Disconnect signal.
■ [0] Disable (default)
■ [1] Enable = Enables the current disconnect service.
✔ FXO Interfaces: The device releases a call when a
current disconnect signal is detected on its port.
✔ FXS Interfaces: The device generates a 'Current
Disconnect Pulse' after the call is released from
the IP side.
Note:
■ The parameter is applicable to FXS and FXO
interfaces.
■ The current disconnect duration is configured by the
CurrentDisconnectDuration parameter.
■ The current disconnect threshold (FXO only) is
configured by the CurrentDisconnectDefaultThreshold
parameter.
■ The frequency at which the analog line voltage is
sampled is configured by the
TimeToSampleAnalogLineVoltage parameter.
■ The corresponding global parameter is
EnableCurrentDisconnect.
- 450 -