CHAPTER23 Digital PSTN
Mediant 1000 Gateway & E-SBC | User's Manual
Parameter Description
configure voip >
interface e1-t1 >
clock-masterclock-
master
[ClockMaster]
[0] Recovered = (Default) Generate the clock according to
the Rx of the E1/T1 line.
[1] Generated = Generate the clock according to the
internal TDM bus.
Note:
If you are modifying the parameter for an existing
(configured) trunk through the Web interface, you must
first stop the trunk.
The source of the internal TDM bus clock is determined by
the parameter TDMBusClockSource.
The parameter is applicable only to E1/T1 interfaces.
'Auto Clock Trunk Priority'
configure voip >
interface e1-t1|bri >
clock-priority clock-
priority
[AutoClockTrunkPriority]
Defines the trunk priority for auto-clock fallback (per trunk
parameter).
The valid range is 0 to 100, where 0 (default) is the highest
priority and 100 indicates that the device does not perform a
fallback to the trunk (typically, used to mark untrusted source
of clock).
Note:
If you are modifying the parameter for an existing
(configured) trunk through the Web interface, you must
first stop the trunk.
Fallback is enabled when the
TDMBusPSTNAutoClockEnable parameter is set to 1.
'Line Code'
configure voip >
interface e1-t1 >
line-code
[LineCode]
Selects B8ZS or AMI for T1 spans, and HDB3 or AMI for E1
spans.
[0] B8ZS = (Default) B8ZS line code (for T1 trunks only).
[1] AMI = AMI line code.
[2] HDB3 = HDB3 line code (for E1 trunks only).
Note:
If you are modifying the parameter for an existing
(configured) trunk through the Web interface, you must
first stop the trunk.
The parameter is not configurable for BRI interfaces; the
device automatically uses the Modified Alternate Mark
Invert (MAMI) line code.
'Line Build Out Loss'
configure voip >
interface e1-t1 >
ilne-build-out-loss
[LineBuildOut.Loss]
Defines the line build out loss for the selected T1 trunk.
[0] 0 dB (default)
[1] -7.5 dB
[2] -15 dB
[3] -22.5 dB
Note:
If you are modifying the parameter for an existing
(configured) trunk through the Web interface, you must
first stop the trunk.
The parameter is applicable only to T1 trunks.