Maintenance Object Repair Procedures
555-233-123
10-226 Issue 4 May 2002
2500
or
none
ABORT Internal system error or administration problem
1. Determine if any B-channels are administered.
2. If there are none, then this is a normal ABORT, since this
test cannot run unless at least one B-channel is
administered.
3. If at least one B-channels is administered, there is an
internal system error. Retry the command at 1-minute
intervals a maximum of 5 times.
FAIL Internal system error
1. See description of ABORT with Error Code 2500.
PASS A message was sent to the far-end switch or terminal adapter.
The ISDN PRI specification allows up to 2 minutes for a reply.
1. Check the Error Log for ATM-SGRP errors of type 2305 for
evidence of a Remote Layer 3 Query failure.
2. If no new errors were logged since this test was run, then
this switch and the far-end switch can exchange call control
messages.
3. If there is still a problem with a particular ATM trunk, busyout
the trunk and run the long test sequence, paying particular
attention to the results of Test #258 (ISDN Test Call).
Table 10-85. TEST #1291 Remote Layer 3 Query — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page