ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 4 May 2002
10-241 555-233-123
System Technician-Demanded Tests:
Descriptions and error codes
Investigate problems in the order presented. When you clear one of the error
codes associated with a test, you clear errors generated by other tests in the
testing sequence. If you clear errors out of order, you can lose important
information.
Connection Audit Test (#50)
Nondestructive (in a sane switch environment).
The Connection Audit test updates TDM time slots. It sends network-update
Control Channel Message Set (CCMS) messages that tell the ATM-TRK circuit
pack to listen to, talk to, or disconnect particular time slots.
The test passes if software successfully sends the downlink network-update
messages. It aborts otherwise.
!
CAUTION:
Though normally nondestructive, this test could unintentionally tear down an
active call if the connection-manager software’s tables are corrupt.
Table 10-94. System Technician-Demanded Tests: ATM-TRK
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset
Board
Sequence D/ND
1
1 D = Destructive, ND = Nondestructive
ATM Board Time Of Day Update (#1261) X ND
Connection Audit Test (#50) X ND
Control Channel Loop Test (#52) X ND
Packet Interface Loop Around Test (#598) X X ND
ATM DSP Test (#1293) X X ND
ATM Board Framer Looparound Test
(#1260)
XD
ATM Board Error Query Test (#1259) X X ND
ATM Cross Talk Test (#1298) X ND
ATM Board Reset (#1256) X D
Continued on next page