BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI
ISDN-BRI Port)
Issue 4 May 2002
10-275 555-233-123
Table 10-109. TEST #617 Loop Around Test
Error
Code
Te s t
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available.
The port may be busy with a valid call. Use the display port
PCSSpp command to determine the station extension or trunk
group/member number of the port. Use the status bri-port
PCSSpp command to determine the service state of the port.
If the service state indicates that the port is in use, then the
port is unavailable for certain tests. Wait until the port is idle
before retesting.
1. If the port status is idle, then retry the command at
1-minute intervals a maximum of 5 times.
1004 ABORT The port has been seized by a user for a valid call. Use the
status station command for the station associated with this
port and determine when the port is available for testing.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
1005 ABORT This test is not valid for this type of translation. Ports
administered as ASAI or ADJK cannot run this test,
because the B channels associated with the port are not used
by ASAI or Avaya Adjunct Links. This is a normal condition.
2012 ABORT Internal System Error.
2100 ABORT Could not allocate the necessary resources to run this test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1, 2 FAIL The NPE of the tested port was found to be transmitting in
error. This causes noisy and unreliable connections. Error
code 1 indicates that the NPE Crosstalk Test failed on
Channel B1. Error code 2 indicates that the NPE Crosstalk
Test failed on Channel B1.
1. Replace circuit pack.
PASS The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, repeat
this test a maximum of 10 times to make sure it continues
to pass.
2. If complaints still exist, examine the station, connections,
and wiring.
Continued on next page