BRI-SET, ASAI-ADJ, BRI-DAT
Issue 4 May 2002
10-307 555-233-123
For all endpoint types, a signaling link becomes unbound when it is
disconnected at Layer 2. For BRI endpoints supporting MIM initialization, a
signaling link may also become unbound if a subsequent attempt to perform
SPID initialization on a bound link fails, (that is, wrong SPID is entered into the
endpoint by the user).
Table 10-122. TEST #626 Signaling Link Status Test
Error
Code
Te s t
Result Description/Recommendation
1139 ABORT The Packet Bus in the port network is out-of-service.
1. Follow the repair procedures for the Packet Bus.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the BRI Port
Local LAN Loop Around Test to verify the repair.
1141 ABORT The PKT-CTRL is out-of-service.
1. Refer to PKT-CTRL (Packet Control Circuit Pack)
Maintenance documentation.
2. If Step 1 does not resolve the problem, escalate to the
next tier.
1144 ABORT The PPN Packet Bus is out-of-service.
1. Follow the repair procedures for the Packet Bus in the
PPN.
2. After completing Step 1, execute the test port long
PCSSpp command, and review the results of the BRI Port
Local LAN Loop Around Test to verify the repair.