Maintenance Object Repair Procedures
555-233-123
10-330 Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Val ues
System Technician-Demanded Tests: Descriptions
and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the Battery & Battery
Charger Query Test, for example, you may also clear errors generated from other
tests in the testing sequence.
Cabinet Sensors Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test environment P sh r 1
1 Any Cabinet Temperature
Query Test (#122)
MINOR ON test environment P sh r 3
257 Any Cabinet Temperature
Query Test (#122)
MAJOR ON test environment P sh r 3
Table 10-128. System Technician-Demanded Tests: CABINET
Order of Investigation
Short Test
Sequence
Long Test
Sequence D/ND
1
1 D = Destructive, ND = Non-destructive
Battery & Battery Charger Query Test (#5) (a) X X ND
AC Power Query Test (#78) (b) X X ND
Power Unit Query Test (carrier E) (#127) (c) X X ND
Power Unit Query Test (carrier D) (#127) (c) X X ND
Power Unit Query Test (carrier A) (#127) (c) X X ND
Power Unit Query Test (carrier B) (#127) (c) X X ND
Power Unit Query Test (carrier C) (#127) (c) X X ND
Emergency Transfer Query Test (#124) (d) X X ND
Cabinet Temperature Query Test (#122) X X ND
External Alarm Lead Query Test (#120) (e) X X ND
Analog Ring Generator Initialization Test (#117) (f) X X ND
Analog Ring Generator Query Test (#118) (f) X X ND