Maintenance Object Repair Procedures
555-233-123
10-392 Issue 4 May 2002
PASS Both port carrier power units in the tested carrier were found to
be healthy by the Maintenance/Tape Processor in a PPN for a
High or Critical Reliability system, the Duplication Interface
circuit pack in a PPN for a High or Critical Reliability system, or
the EPN Maintenance circuit pack in an EPN multicarrier
cabinet system. If the status LEDs on both port carrier power
units are not showing green, the PR-MAINT
(Maintenance/Tape Processor), DUPINT (Duplication
Interface) circuit pack, or the EPN MAINT (Maintenance)
circuit pack may have incorrectly reported the state of the port
carrier power units. Look for and resolve any alarms on these
MOs.
Table 10-144. TEST #127 Power Unit Query Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page