CLAN-BD (Control LAN Circuit Pack)
Issue 4 May 2002
10-407 555-233-123
Congestion Query Test (#600)
This non-destructive test queries the number of used buffers to determine if the
CLAN circuit pack is congested.
Normal call handling resumes when the CLAN circuit pack has recovered from
congestion.
2012 ABORT Could not allocate the necessary system resources to run test.
2100 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
FAIL Circuit pack has detected a failure of the Packet Interface Test
(#598).
1. Retry command at 1-minute intervals, up to 5 times.
2. If the problem persists, reset the circuit pack (reset board
UUCSS).
3. If the test continues to fail, replace the circuit pack.
PASS The Packet Interface Test (#598) passed.
If: Then:
Used buffers are, or are
nearly, exhausted,
The test fails
The test fails, The switch redirects outgoing calls to another available
CLAN, and denies new incoming calls
Table 10-151. TEST #598 Packet Interface Test — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page