Maintenance Object Repair Procedures
555-233-123
10-416 Issue 4 May 2002
1-3 FAIL DTMF digits were not detected correctly. This may or may not
impact reception of R2-MFC calls.
1. Run the short test sequence via the test port PCSSpp sh
r 1 command.
2. If the problem persists, the system is still operating
properly but system capacity will be reduced. In order to
restore system performance to normal, replace the Call
Classifier circuit pack containing the defective CLSFY-PT
(Call Classifier Port).
101-122 FAIL Forward or Backward MFC signals were not correctly
generated or detected. This impacts reception of incoming
MFC calls.
1. Run the short test sequence via the test port PCSSpp sh
r 1 command.
2. If the problem persists, the system is still operating
properly but system capacity will be reduced. In order to
restore system performance to normal, replace the Call
Classifier circuit pack containing the defective CLSFY-PT
(Call Classifier Port).
PASS Tone Detection Verification is successful. The Call Classifier
Port (CLSFY-PT) is able to detect/generate all necessary
tones.
Table 10-155. TEST #42 Tone Detection Verification Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page