2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2053 ABORT At least one of the following errors was found on the DS1
circuit pack: loss of signal (1281), blue alarm (1793), red alarm
(2049), yellow alarm (2305), or hyperactivity (1537).
1. Look for the above error types in the Hardware Error Log
and follow the procedures given in the appropriate
DS1-BD or UDS1-BD maintenance documentation for the
listed error types.
Table 10-160. TEST #7 Conference Circuit Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page