1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS (TDM-Bus) Maintenance documentation to
diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute
intervals a maximum of 5 times.
Table 10-167. TEST #6 NPE Crosstalk Test Continued