Maintenance Object Repair Procedures
555-233-123
10-486 Issue 4 May 2002
Error Log Entries and Test to Clear Values
a. Error Type 0: Switch has removed circuit pack has been removed or circuit
pack has been insane for more than 11 minutes.
1. Reinsert the circuit pack.
2. Verify that the alarm clears.
3. If problem persists, replace the circuit pack.
System Technician-Demanded Tests: Descriptions
and Error Codes
Two system technician test commands include the Data Channels (DATA-CHLs).
■ The test data-module ext [short | long] command tests the single
DATA-CHL, specified by ext.
■ The test network-control [short | long] command tests each
administered DATA-CHL that resides on the TN777B Netcon or
TN2401/TN794 NetPkt circuit pack in the specified carrier.
Table 10-177. Data Channel Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
(a)
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test data-module ext sh r 1
1 Any Local Loop Back Test
(#111)
MINOR ON test data-module ext sh r 3
18 0 busyout data-module
ext
WARNING OFF release data-module ext
130 None WARNING ON test data-module ext sh
257 Any Remote Maintenance
Looparound Test
(#109)
MINOR ON test data-module ext sh r 5
513 Any Crosstalk Test (#110) MINOR ON test data-module ext sh r 3
769 Any Dual Port RAM Test
(#108)
MINOR ON test data-module ext l r 3