DATA-CHL (Data Channel)
Issue 4 May 2002
10-499 555-233-123
14
16
40
2000
2003
2004
FAIL
(contd.)
a. Test #110 result is either PASS or FAIL and Test #111 result
is FAIL (for target DATA-CHL): the target DATA-CHL, or
Netcon or NetPkt circuit pack are probably defective.
1. Busyout the links to all DATA-CHLs (busyout
link).
2. Test the target DATA-CHL (test data-module
ext long).
3. If Test #107 result or Test #108 is FAIL, replace
the Netcon or NetPkt circuit pack when
convenient.
4. Reset Time-of-Day clock on new circuit pack
(set time).
5. Repeat the test.
6. If Test #107 result is PASS, and Test #108
result is FAIL,
7. Replace the Netcon or NetPkt circuit pack
when convenient.
8. Repeat the test.
b. If both Test #107 result and Test #108 results ARE PASS,
the target DATA-CHL is defective.
1. Remove target DATA-CHL from operation
(remove data-module ext).
2. Replace the Netcon or NetPkt circuit pack
when convenient.
3. Reset Time-of-Day clock on new circuit pack
(set time)
4. Restore any busied-out links.
PASS DATA-CHLs establish connections.
Table 10-182. TEST #110 Data Channel Crosstalk Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page