Maintenance Object Repair Procedures
555-233-123
10-502 Issue 4 May 2002
2003 ABORT Internal system error
1. Retry the command at 1-minute intervals, up to 5 times.
40
2000
2003
2004
FAIL Error Code 40: Local Loop Back Test faileddata corrupt.
Error Code 2000-2004: Local Loop Back Testdata lost.
1. Determine if links exist on DATA-CHLs (status link).
2. Busyout the links to all DATA-CHLs (busyout link).
3. Test the target DATA-CHL (test data-module ext long).
4. If Test #107 result is FAIL, replace the Netcon or NetPkt
circuit pack when convenient.
5. Reset Time-of-Day clock on new circuit pack (set time).
6. Repeat the test.
7. If Test #107 result is PASS, and Test #108 result is FAIL,
replace the Netcon or NetPkt circuit pack when convenient.
8. Repeat the test.
9. If both Test #107 result and Test #108 results ARE PASS,
the target DATA-CHL is defective.
10. Remove target DATA-CHL from operation (remove
data-module ext).
11. Replace the Netcon or NetPkt circuit pack when convenient.
12. Reset Time-of-Day clock on new circuit pack (set time).
13. Restore any busied out links.
PASS DATA-CHLs establish connections.
Table 10-183. TEST #111 Data Channel Local Loop Back Test Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page