DAT-LINE (Data Line)
Issue 4 May 2002
10-513 555-233-123
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1-minute intervals for a maximum of
5 times.
2. If the test continues to abort, escalate the problem.
2003 ABORT Failed to receive an off-hook from the Data Line.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2004 ABORT Failed to receive an off-hook from the Network Control Data
Channel.
2005 ABORT The handshake between the data channel and the data line
port failed.
1. Look for DATA-CHL errors in the Error Log. If present,
refer to DATA-BD (Network Control Circuit Pack)
Maintenance documentation.
2. Retry the command at 1-minute intervals a maximum of 5
times.
3. If the test still aborts, replace the circuit pack.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at 1-minute intervals a maximum of 5
times.
Table 10-189. TEST #171 Digital Loop Around Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page

Table of Contents