DC-POWER
Issue 4 May 2002
10-517 555-233-123
Single-Carrier Cabinet Power Query Test (#79)
This test queries the Maintenance/Tape Processor (in a PPN) or the EPN
Maintenance circuit pack (in an EPN) about the status of the power in a
single-carrier cabinet system. This test can only detect power problems in carriers
in the Port Network for which the Carrier Port Power Unit is physically present.
Table 10-191. TEST #79 Single-Carrier Cabinet Power Query Test
Error
Code
Tes t
Result Description/Recommendation
1000 ABORT System resources required to run this test are not available.
1. Retry the command at 1minute intervals a maximum of 5
times.
2000 ABORT Response to the test request was not received within the
allowable time period.
1. Retry the command at 1minute intervals a maximum of 5
times.
2. If the test continues to ABORT with Error Code 2000, check
for system powering problems with the A cabinet (PPN or
EPN). Resolve all DC-POWER alarms. Then, repeat the
test. If the test continues to ABORT with a 2000 Error Code,
resolve all DUPINT (Duplication Interface Circuit Pack)
errors in a PPN for a high or critical reliability system, or
MAINT (EPN Maintenance circuit pack) errors in an EPN.
Then, repeat the test.