DID-DS1 (DS1 DID Trunk)
Issue 4 May 2002
10-529 555-233-123
PASS The port can correctly conference multiple connections.
User-reported troubles on this port should be investigated using
other port tests and by examining station, trunk, or external wiring.
NOTE:
This test always passes for TN712 Analog circuit packs prior
to Vintage 14 and for TN742 prior to Vintage 4.
0NO
BOARD
The test could not relate the internal ID to the port (no board). This
could be due to incorrect translations, no board is inserted, an
incorrect board is inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the
lIst config command and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue
the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish
the linkage between the internal ID and the port. If this is not the
case, check to see that there is a valid board inserted.
Table 10-194. TEST #7 Conference Circuit Test — Continued
Error
Code
Tes t
Result Description/Recommendation