DID-TRK (DID Trunk)
Issue 4 May 2002
10-545 555-233-123
0NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct.
Translate the board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish
the linkage between the internal ID and the port.
Table 10-198. TEST #33 Loop Around and Conference Circuit Test — Continued
Error
Code
Te s t
Result Description/Recommendation