Maintenance Object Repair Procedures
555-233-123
10-552 Issue 4 May 2002
Notes:
a. Error Type 1: this error reports the registration status of the endpoint. If call
processing SW claims the endpoint is registered and receives keep-alive
handshakes from the endpoint, the test passes. If keep-alive handshaking
has failed, the test fails. If the user has intentionally un-registered from
Avaya DEFINITY Server, the station is now basically an AWOH station and
is no longer being maintained; no tests run for this station.
b. Error Type 18: this error type is logged when the port/station is busied out
by maintenance personal. Make sure the port/station is released from busy
via the release port/station command (IP terminal only).
c. Error Type 257: this error tracks failures of the signaling path PING test.
The test attempts to send a PING packet to the endpoint IP address, as
reported during registration. The PING packet originates with the C-LAN
board through which the endpoint is registered. If the PING response
packet is received, the test passes. If the PING response packet times out,
the test fails.
Table 10-201. DIG-IP-STN Digital IP Station Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0 0 Any Any test station extension
1 (a) Registration Status Inquiry
(#1372)
WARNING OFF
18 (b) 0 Busyout port or station WARNING OFF release port (or)
station
257 (c) Signaling Path PING Test
(#1373)
WARNING OFF
(d) Digital Terminal Lamp
Update (#16)
WARNING OFF
(e) Digital Terminal Audit
Update (#17)
WARNING OFF
513 (f) Any Station Digital AUDIT Test
(#17)
WARNING OFF test port or station
1281
(g)
Any Station Digital AUDIT Test
(#17)
WARNING OFF test port or station
1537
(h)
40968 WARNING OFF test port or station
2305 (i) Any None
2817 (j) Station Hyperactivity
Continued on next page