DIG-LINE (Digital Line)
Issue 4 May 2002
10-565 555-233-123
Possible reasons for terminal being not downloaded include:
— Terminal is off-hook.
— Terminal detected a bad checksum.
— Terminal detected a bad or missing EEPROM (refer to hardware error log).
— Terminal is busy programming data from a previous PROGRAM message.
— Terminal is in the Programming Disabled state.
— Terminal is in the Local Program Options Mode.
— Terminal is disconnected or out of service (use status station command).
Hardware Error Log Entries and Test to Clear
Val ues
Table 10-209. DIG-LINE Error Log Entries
Error Type Aux Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port PCSSpp sh r 1
1 (a) 40987 None WARNING OFF
1 (b) 1 to 20 None WARNING OFF
18 (c) 0 busyout port
PCSSpp
WARNING OFF rel port PCSSpp
130 (d) None WARNING ON test port PCSSpp sh
257 (e) 40971 None
513 0 Station (Digital)
Audits Test (#17)
WARNING(o) OFF test port PCSSpp sh r 6
767 (f) 40964 None WARNING OFF
769 (g) 40963
40988
None WARNING OFF
1026(o) NONE WARNING OFF
1281 Any Station (Digital)
Audits Test (#17)
WARNING OFF test port PCSSpp sh r 4
1537 (h) 40968 None WARNING OFF
1793 Voice & Ctrl. Local
Loop Test (#13)
MINOR/
WARNING
2
ON test port PCSSpp l r 3
2049 NPE Crosstalk Test
(#9)
MINOR/
WARNING
3
ON test port PCSSpp l r 3
2304 (n) None
2305 (i) 32770 None
2305 (h) 40967 None
Continued on next page