Maintenance Object Repair Procedures
555-233-123
10-578 Issue 4 May 2002
1002 ABORT The system could not allocate time slots for the test. The
system may be under heavy traffic conditions or it may have
time slots out-of-service due to TDM-BUS errors. Refer to
TDM-BUS (TDM Bus) Maintenance to diagnose any active
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling
heavy traffic, repeat test at 1-minute intervals a maximum
of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT (Tone Generator) Maintenance
documentation.
3. If neither condition exists, retry the command at 1-minute
intervals a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has
been aborted. Use display port PCSSpp to determine the
station extension or attendant number of the port. Use status
station or status attendant to determine the service state of
the port. If the service state indicates that the port is in use,
then the port is unavailable for certain tests. You must wait
until the port is idle before retesting. Attendants are always in
use (off-hook) if the handset is plugged in and the port is not
busied out.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort and the port is not in use,
escalate the problem.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Rerun the test at 1-minute intervals a maximum of 5 times.
Table 10-214. TEST #13 Voice and Control Channel Local Loop Test — Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page