Maintenance Object Repair Procedures
555-233-123
10-604 Issue 4 May 2002
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of tone detectors
present or some tone detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer
to TTR-LEV Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer
to TONE-PT Maintenance documentation.
3. If neither condition exists, retry the test at one-minute
intervals a maximum of 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has
been aborted. Use the display port PCSSpp command to
determine the trunk group/member number of the port. Use the
status trunk command to determine the service state of the
port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. You must wait until the
port is idle before retesting.
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this
test.
1. Retry the command at one-minute intervals a maximum of
5 times.
Any FAIL The NPE of the tested port was found to be transmitting in
error. This causes noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port is correctly using its allocated time slots.
User-reported troubles on this port should be investigated by
using other port tests and by examining trunk or external
wiring.
Table 10-225. TEST #6 NPE Crosstalk Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page