DS1-BD (DS1 Interface Circuit Pack)
Issue 4 May 2002
10-625555-233-123
SAKI Sanity Test (#53)
This test is destructive. This test resets the circuit pack.
Table 10-233. TEST #53 SAKI Sanity Test
Error
Code Test Result Description/Recommendation
None ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1005 ABORT Wrong circuit pack configuration to run this test. This error
applies only to DS1 Interface circuit packs. It means the DS1
Interface circuit pack is providing timing for the system and,
therefore, it cannot be reset without major system disruptions.
1. If the circuit pack needs to be reset, then set
synchronization to another DS1 Interface circuit pack or
to the Tone-Clock circuit pack and try again. Refer to
“SYNC (Synchronization)”.
1015 ABORT Port is not out-of-service.
1. Busyout the circuit pack.
2. Execute the command again.
2100 ABORT System resources required for this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1 FAIL The circuit pack failed to reset.
Continued on next page