DS1-BD (DS1 Interface Circuit Pack)
Issue 4 May 2002
10-627555-233-123
When the test is complete, the maintenance software sends a stop loop around
message to the DS1 Interface circuit pack to put the circuit pack back into the
normal operation mode. All trunks of the DS1 Interface circuit pack are restored to
the in-service state after the release board command is entered
Table 10-234. TEST #135 Internal Looparound Test
Error
Code
Tes t
Result Description/Recommendation
2012 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5
times.
1002 ABORT The system could not allocate time slots for the test. The system
may be under heavy traffic conditions or it may have time slots
out-of-service due to TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy
traffic, repeat test at 1-minute intervals a maximum of 5
times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the test at 1-minute intervals
a maximum of 5 times.
1004 ABORT Received an incoming call on a port of the DS1 circuit pack
during the test.
1. Enter the busy-out board UUCSS command to put all
trunks of DS1 Interface circuit pack to out-of-service state.
2. Retry the command at 1-minute intervals a maximum of 5
times.
1015 ABORT Ports on DS1 Interface circuit pack have not been busied out.
1. Enter the busy-out board UUCSS command to put all
trunks of the DS1 Interface circuit pack into out-of-service
state.
2. Retry the command.
Continued on next page