Maintenance Object Repair Procedures
555-233-123
10-744 Issue 4 May 2002
Ethernet Local Looparound Test (#1278)
This test is destructive.
Use this test to check circuitry in the data path for an Ethernet call (from the
on-board processor to the Ethernet Transceiver). This test fails if the data it
receives does not match the data it transmits.
Table 10-280. TEST #1278 Ethernet Local Looparound Test
Error
Code
Tes t
Result Description/Recommendation
1000 ABORT The port is in use.
1. Determine status of port (status clan-port UUCSSpp).
2. Retry the command when the port is idle. The post may be
forced to the idle state by executing a busyout port UUCSS
command.
NOTE:
The busyout port command is destructive, causing all
calls and links associated with the port to be torn down.
2000 ABORT Did not receive circuit pack test response within the allowable
time period.
1. If the problem persists, reset the circuit pack (busyout
board UUCSS, reset board UUCSS, and release board
UUCSS).
2. If the problem persists, replace the circuit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. If the problem persists, escalate the problem.
2100 ABORT Could not allocate the necessary resources to run test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. If the problem persists, escalate the problem.
1 FAIL Circuit pack detected failure in the Ethernet Local Looparound
Test (#1278).
1. If the problem persists, reset the circuit pack (busyout
board UUCSS, reset board UUCSS, and reset board
UUCSS).
2. If the problem persists, replace the circuit pack.
PASS The circuitry tests properly.
Continued on next page