1002 ABORT The system could not allocate time slots for the test on either
TDM Bus. The system may be under heavy traffic conditions or it
may have time slots out-of-service due to TDM-BUS errors. Refer
to TDM-BUS (TDM Bus) Maintenance documentation to diagnose
any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy
traffic, repeat the test at 1-minute intervals a maximum of 5
times.
1003 ABORT The system could not allocate a tone receiver for the test. The
system may be oversized for the number of Tone Detectors
present or some Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If these errors are
present, refer to TTR-LEV (TTR Level) Maintenance
documentation. Even if there are no TTR-LEV errors, there
still may not be a Tone Detector available on the network that
contains the circuit pack being tested. Verify that there is at
least one Tone Detector on this network. If not, this test
always aborts for this Expansion Interface circuit pack. This
does not harm the system in any way.
2. Look for TONE-PT errors in the Error Log. If present, refer to
TONE-PT (Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a
maximum of 5 times.
1031 ABORT A query of the Expansion Interface circuit pack aborted. The
purpose of this query was to see if the Expansion Interface circuit
pack could detect the framing signal.
1. If Test #238 aborted, follow the procedure associated with
this abort code.
2. If Test #238 did not abort, rerun Test #240 at 1-minute
intervals a maximum of 5 times.
3. If Test #240 continues to abort without Test #238 aborting,
escalate the problem.
1032 ABORT The Expansion Interface circuit pack cannot detect the framing
signal and cannot run the test.
1. Refer to the errors for Test #238 to determine why the
Expansion Interface circuit pack is out-of-frame.