Maintenance Object Repair Procedures
555-233-123
10-794 Issue 4 May 2002
2000 ABORT Response to the test request was not received within the
allowable time period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2060 ABORT The link on the Packet Bus being used to perform the test has
failed.
1. Retry the command at 1-minute intervals a maximum of 5
times.
2. If the test continues to abort, check for problems with the
Packet Control circuit pack (look for PKT-CTL errors).
2500 ABORT An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals a maximum of 5
times.
1 FAIL The test did not detect the test tone through the loop around
connection.
NOTE:
If the circuit pack is a TN570, the packet portion of this
test was not run since the circuit portion failed.
1. Test the Active Tone-Clock on the Port Network that
contains the defective Expansion Interface circuit pack to
verify that dial tone is being supplied.
2. If the Tone-Clock is healthy, issue the test board PCSS
long command on the Expansion Interface circuit pack.
3. If this test continues to fail, replace the Expansion
Interface circuit pack or transceiver. Then, reissue the test
board PCSS long command on the new Expansion
Interface circuit pack.
Table 10-293. TEST #242 Expansion Interface Lightwave
Transceiver Loop Around Test Continued
Error
Code
Te s t
Result Description/Recommendation
Continued on next page