EXP-INTF (Expansion Interface Circuit Pack)
Issue 4 May 2002
10-809555-233-123
1141 ABORT The Packet Control circuit pack is out-of-service.
1. Determine if the Packet Control circuit pack is busied out.
(This is indicated by an Error Type 18 logged against
PKT-CTRL.) If it is, release it via the release
packet-control command, and retry the command.
2. If the Packet Control circuit pack is NOT busied out, refer to
PKT-CTRL Maintenance documentation for the repair
procedure for the Packet Control circuit pack.
1144 ABORT The Packet Bus in the PPN has a major alarm active against it.
1. Resolve the alarm in the PPN.
2. Retry the command.
1195 ABORT An EI link switched during this test.
1. Retry the command at 1-minute intervals a maximum of 3
times.
1421 ABORT This abort code is valid and can appear only when the
Expansion Interface circuit pack addressed in the test command
is one which terminates the link between two the EPNs. It
indicates that the test failed, but that this test was run on the
EPN EI circuit pack that:
a. is in the same EPN as the circuit pack under test,
b. is on the active link and
c. terminates the fiber from the PPN.
The EI tested is probably not at fault.
1. Enter display alarms and follow the EXP-INTF repair
procedures for the EPN EI that:
a. is in the same EPN as the circuit pack just tested here
b. is on the active link, and
c. terminates the fiber from the PPN.
2. If there are no alarms logged against that EI, run Test #589
on it and follow procedures for this test.
3. Try this command again.
Table 10-296. TEST #589 Expansion Interface Packet Interface Test — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page