H323-SGRP (H.323 Signaling Group)
Issue 4 May 2002
10-877555-233-123
Table 10-316. TEST #1387 H.323 Signaling Group Ping Test
Error
Code
Test
Result Description/Recommendation
1, 2 ABORT Internal Error.
1. Retry the command at 1-minute intervals a maximum
of 3 times.
7 ABORT Destination unreachable.
1. Verify that the CLAN has been administered with an
IP-Route that enables the CLAN to reach the
FAR-END IP address
2. Once verified, execute test sig-group grp#
command to verify that the H.323 Signaling Group
Ping Test (#1387) passes.
1005 ABORT Configuration for this test is incorrect.
1. Verity that the link is in-service with the status port or
status link command. Verify that the routing table
has destinations that are reachable through this port.
2. Repeat the test.
3. If the test aborts with Error Code 7, while step 1
verified, escalate the problem.
1125 ABORT Link is not in service.
1. Check if the link is in-service or not. If the link is not in
service, release the link using release link or release
port command and repeat the test. This is a normal
abort.
2. If the test continues to abort after following the repair
procedures, escalate the problem.
2000 ABORT Response to the test was not received from the CLAN circuit
pack within the allowable time period.
1. If this result occurs repeatedly, attempt to reset the
circuit pack if the other ports on the board are not in
use (Yellow LED is off). Reset the circuit pack by
issuing the busyout board UUCSS, reset board
UUCSS, and release board UUCSS commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals a maximum
of 3 times.