Loading...
Maintenance Object Repair Procedures
555-233-123
10-888 Issue 4 May 2002
Hardware Error Log Entries and Test to Clear
Val ues
Table 10-322. Hybrid Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test port PCSSpp sh r 1
1 (a) Any None WARNING OFF
15 (b) Any Hybrid Audits Test
(#61)
18 (c) 0 busyout port
PCSSpp
WARNING OFF release port PCSSpp
130 (d) None WARNING ON test port PCSSpp sh
257 (e) 40988 None MIN/WRN
2
2 Major or Minor alarms on this MO may be downgraded to Warning alarms based on the values used
in the set options command.
OFF
513 (f) 40965 Hybrid Line Audits
Test (#61)
WARNING OFF test port PCSSpp sh r 4
769 (g) Remote Dig Loop
Around Test (#59)
WARNING OFF test port PCSSpp sh r 3
1025 Hybrid & Conf.
Circuits Test (#57)
MIN/WRN
2
ON test port PCSSpp l r 3
1281 (h) Local Digital Loop
Around Test (#58)
WARNING ON test port PCSSpp l r 3
1537 (i) 40968 None WARNING OFF
1793 TDMNPE Crosstalk
Test (#6)
MIN/WRN
2
ON test port PCSSpp l r 3
2049 (j) 32770 None
2049 (k) 40967 None
Continued on next page