Maintenance Object Repair Procedures
555-233-123
10-898 Issue 4 May 2002
7 FAIL Conference Test failed. User may be able to use conference
circuit without difficulty in some cases. In other extreme cases,
conference calling will be totally restricted.
The failure may be due to off-board circumstances, the most
common of which is an off-hook occurring during the test. Also,
check the error logs against the GPTD-BD, the TONE-BD, and
the TONE-PT.
1. This error can be caused by a disconnected terminal.
First, ensure that the terminal is connected and the wiring
is OK.
2. Then, issue display port and status station to determine
if the station is idle. If it is idle, issue test port for this port.
3. If test continues to fail, issue busyout port and release
port, and then retest the port.
4. It is possible that the port may still be functional from a
user’s point of view.
Table 10-326. TEST #57 Hybrid Circuit and Conference Circuit Test — Continued
Error
Code
Tes t
Result Description/Recommendation
Continued on next page