Table 10-330. TEST #61 Hybrid Line Audits Test
Error
Code
Te s t
Result Description/Recommendation
ABORT Internal System Error
1 ABORT The test was aborted due to an internal system error during
the switchhook audit.
2 ABORT Internal System Error occurred during bad scan inquiry audit.
1. Make sure that the station is not in an out of service state.
2. Retry the command at 1-minute intervals a maximum of 5
times.
3 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out)
for this port. If this error type is present, the release the
port via release station <extension> and run the test
again.
2. Make sure that the terminal is connected.
3. Retry the command at one-minute intervals a maximum of
5 times.
1000 ABORT System resources required to run this test are not available.
The port may be busy with a valid call. Use display port
PCSSpp to determine the station extension number of the
port. Use status station to determine the service state of the
port. If the service state indicates that the port is in use, then
the port is unavailable for certain tests. (Refer to the Status
Commands section in Chapter 10, Maintenance Commands
and Trouble-Clearing Aids for a full description of all possible
states.) You must wait until the port is idle before retesting.
Attendants are always in use (off-hook), if the handset is
plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at
one-minute intervals a maximum of 5 times.
Continued on next page