Maintenance Object Repair Procedures
555-233-123
10-920 Issue 4 May 2002
Error Log Entries and Test to Clear Values
Table 10-334. DS1 Interface Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1 Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0 Any Any Any test board UUCSS
1(a) 0 Circuit pack removed or
SAKI Test (#53)
MIN/WRN OFF
18(b) 0 busyout board UUCSS WARNING OFF release board UUCSS
23(c) 0 Board administered but not
inserted
WARNING OFF add ds1 UUCSS
125(d) none Wrong board MINOR ON
257(e) 65535 Control Channel Loop Test
(#52)
MINOR ON test board UUCSS l r
20
513(f) 4352
4353
4355
4356
4358
TN2302 On board hardware
errors
MINOR ON
1025(g) Any FPGA Query Test (#1406) MINOR
1281(h) Any TSI Health Query Test
(#1406)
1538(i) Any Circuit pack is hyperactive MINOR ON
1793 Any NIC Loss Of Signal MIN/WRN
2
2 Minor alarms on this MO may be downgraded to warning alarms based on values set in the set
options command.
test board UUCSS l r 2
2049(j) Any PPC Sanity Query Test
(#1406)
2305(k) Any IP Address Update
2561(l) Ping error
2817(m) Any Ethernet Hardware Query
Test (#1406)
3073(n) Any Circuit pack reset Test (#53)
3840,
3841(o)
Inconsistent downlink or
board error
3999(p) Any None